UniKey Updater And Generator Tool: Difference between revisions

From SecuTech Wiki
Jump to navigationJump to search
Joseph (talk | contribs)
No edit summary
Joseph (talk | contribs)
No edit summary
Line 38: Line 38:
[[Image:UniKey_RemoteUpdate_Tool_Pic03.jpg]]
[[Image:UniKey_RemoteUpdate_Tool_Pic03.jpg]]


In the "Add Memory" window, the data field displays the data that will overwrite the contents of the target UniKey device's memory, beginning from position [Start Address] of the input data's [Length]. Data can be loaded in through [Load], loading the hexidecimal values of the file, and saved through [Save].
In the "Add Memory" window, the data field displays the data that will overwrite the contents of the target UniKey device's memory, beginning from position [Start Address] of the input data's [Length]. Data can be loaded in through [Load], loading the hexidecimal values of the file, and saved through [Save].


Memory records can be later edited or deleted from the "Memory Settings" tab.
Memory records can be later edited or deleted from the "Memory Settings" tab.
Line 48: Line 48:
[[Image:UniKey_RemoteUpdate_Tool_Pic04.jpg]]
[[Image:UniKey_RemoteUpdate_Tool_Pic04.jpg]]


Clicking [Add] will open the "Add Module" window, as shown below. The add a module, input the module number, between 0 and 63 inclusive, and value, between 0 and 65535 inclusive. Checking the [Autodecremen] option will automatically decrement the module's value. <!--Check-->
Clicking [Add] will open the "Add Module" window, as shown below.


[[Image:UniKey_RemoteUpdate_Tool_Pic05.jpg]]
[[Image:UniKey_RemoteUpdate_Tool_Pic05.jpg]]
In the "Add Module" window, input the module number, between 0 and 63 inclusive, and value, between 0 and 65535 inclusive to add a new module. Checking the [Autodecrement] option will automatically decrement the module's value by default.<!--Check-->


Modules can be later edited or deleted from the "Module Settings" tab.
Modules can be later edited or deleted from the "Module Settings" tab.
Line 62: Line 64:
[[Image:UniKey_RemoteUpdate_Tool_Pic07.jpg]]
[[Image:UniKey_RemoteUpdate_Tool_Pic07.jpg]]


<!--J-->Enter a starting point value for the Algorithm. The format of the Algorithm must be written as "A=B+C" and variables can be defined by the customer. To add more than one algorithm use a comma (,) to separate algorithms.
<!--Check, add more useful information for the algorithm syntax and example etc.-->To add a new algorithm in the "Add Algorithm" window, input the start address of the algorithm under [Start Point] (0-127) and the algorithm. The entered algorithm must entered be in the format "A=B+C". To add more than one algorithm, use a comma (,) to separate algorithms. Input that has incorrect syntax will return the error "Invalid algorithm format". Variables can be defined by the end user.


Click OK to add your new Algorithm. All your settings will be listed in the Arithmetic Settings message box. Click Edit to change your settings, and click Delete to remove.
Algorithms can be later edited or deleted from the "Arithmetic Settings" tab.


=== Time Settings ===
=== Time Settings (UniKey Time only) ===


[[Image:UniKey_RemoteUpdate_Tool_Pic08.jpg]]
[[Image:UniKey_RemoteUpdate_Tool_Pic08.jpg]]


Time settings can only be used by UniKey Time, indicating the exact start, end or duration of each corresponding Module No. (0-15), this is designed to enable software renting or leasing. By setting parameters in this section, software vendors can set up a software module No. and its corresponding start time (YY-MM-DD:HH), end time (YY-MM-DD:HH) or duration time (DD:HH). Click Add to add another module, select an item then click Edit to change your settings, or click Delete to remove the selected setting.
Time modules can be set through the "Time Settings" tab, with each time module indicating the exact Start Time and End Time or Duration of each corresponding Module No. (0-15). Selecting the "End Time" option, whereby the module is set to expire once the entered date has been reached, the expiry date is entered in the format (YY-MM-DD:HH), whereas selecting the "Duration" option, whereby the module is set to expire after the entered time has lapsed, the time duration must be entered in the format (DD:HH).


When you click on Add, an add time modules windows will pop up
Clicking [Add] will open the "Add Time Modules" window, as shown below.


[[Image:UniKey_RemoteUpdate_Tool_Pic09.jpg]]
[[Image:UniKey_RemoteUpdate_Tool_Pic09.jpg]]


Enter Module number and Start Time. Either End Time or Duration must be selected to add a time module.
To add a new time module in the "Add Time Modules" window, input the Module No, the Start Time (the time at which the module is enabled) in the format (YY-MM-DD:HH), then either the "End Time" or "Duration" in the correct format of the module.


Click ok to add this Module. Your settings will be displayed in the message box.
Time modules can be later edited or deleted from the "Time Settings" tab.


=== UPT File ===
=== UPT File ===


In the UPT File tab, if you want to generate a password for this update file, please enable the Set File Password check box and input your desired password.
<!--J-->After settings have been configured, the .upt file containing the setting for the UniKey device can be generated through the "UPT File" tab.


[[Image:UniKey_RemoteUpdate_Tool_Pic10.jpg]]
[[Image:UniKey_RemoteUpdate_Tool_Pic10.jpg]]


Click '''Generate'''. A save file window will pop up as below, and you set the directory to save in and a name for the update file.
In the "UPT File" tab, a password can be set for the generated
 
Click [Generate]. A save file window will pop up as below, and you set the directory to save in and a name for the update file.


[[Image:UniKey_RemoteUpdate_Tool_Pic11.jpg]]
[[Image:UniKey_RemoteUpdate_Tool_Pic11.jpg]]

Revision as of 14:38, 25 September 2012


UniKey Remote Update

Remote update allows updating a UniKey device's settings without physical access to the device, often after the device has been deployed and no longer in possession of the software developer.

Typically, if settings on a software protection dongle need to be modified or updated, the device must be sent back to the software developer so that settings can be modified directly to the device by developer, then sent back to the client - a process that is costly and time consuming.

UniKey provides the ability to update a UniKey device's settings without access to the device, remotely.

Remote Update Process

There are two steps involved in remotely updating a UniKey device.:

  1. The Software Vendor generates a UniKey Updater file (*.upt) with the UniKey Generator, specific for the intended UniKey device.
  2. The End User receives the UniKey Updater file (*.upt) sent by the Software Vender, and updates the UniKey device with new settings using UniKey Update.

UniKey Update Generator

The UniKey Update Generator tool is used to creating an update file (*.upt file) for remote end-users. It is used to set settings with the UniKey Updater tool, and provides a useful solution for software vendors to remotely update an end-user’s UniKey device.

Basic Settings

In the Generator window, on the "Basic Settings" tab, input the four passwords of the respective UniKey device to be updated.

  • Bind HID, Bind SID, Bind Module No., Bind Update Tag: Allows software vendors to generate an update file to operate only on a specified UniKey which matches the set parameters.
  • New SID: Allows a software vendor to set a new software ID for the UniKey device.
  • New Update Tag: Allows a software vendor to set a new Update Tag. The Update Tag is solely for the purpose of distinguishing between .upt update files.

Memory Settings

Clicking [Add] will open the "Add Memory" window, as shown below.

In the "Add Memory" window, the data field displays the data that will overwrite the contents of the target UniKey device's memory, beginning from position [Start Address] of the input data's [Length]. Data can be loaded in through [Load], loading the hexidecimal values of the file, and saved through [Save].

Memory records can be later edited or deleted from the "Memory Settings" tab.

Module Settings

"Module Settings" enables you to set your software module no. and module value to your update file.

Clicking [Add] will open the "Add Module" window, as shown below.

In the "Add Module" window, input the module number, between 0 and 63 inclusive, and value, between 0 and 65535 inclusive to add a new module. Checking the [Autodecrement] option will automatically decrement the module's value by default.

Modules can be later edited or deleted from the "Module Settings" tab.

Arithmetic Settings

Clicking [Add] will open the "Add Algorithm" window, as shown below.

To add a new algorithm in the "Add Algorithm" window, input the start address of the algorithm under [Start Point] (0-127) and the algorithm. The entered algorithm must entered be in the format "A=B+C". To add more than one algorithm, use a comma (,) to separate algorithms. Input that has incorrect syntax will return the error "Invalid algorithm format". Variables can be defined by the end user.

Algorithms can be later edited or deleted from the "Arithmetic Settings" tab.

Time Settings (UniKey Time only)

Time modules can be set through the "Time Settings" tab, with each time module indicating the exact Start Time and End Time or Duration of each corresponding Module No. (0-15). Selecting the "End Time" option, whereby the module is set to expire once the entered date has been reached, the expiry date is entered in the format (YY-MM-DD:HH), whereas selecting the "Duration" option, whereby the module is set to expire after the entered time has lapsed, the time duration must be entered in the format (DD:HH).

Clicking [Add] will open the "Add Time Modules" window, as shown below.

To add a new time module in the "Add Time Modules" window, input the Module No, the Start Time (the time at which the module is enabled) in the format (YY-MM-DD:HH), then either the "End Time" or "Duration" in the correct format of the module.

Time modules can be later edited or deleted from the "Time Settings" tab.

UPT File

After settings have been configured, the .upt file containing the setting for the UniKey device can be generated through the "UPT File" tab.

In the "UPT File" tab, a password can be set for the generated

Click [Generate]. A save file window will pop up as below, and you set the directory to save in and a name for the update file.

Congratulations! You have generated the Update file if you see the window below.

Remote Updater

General Information about the Remote Updater

It is a common need for software vendors to upgrade the software at the end-user side. UniKey provides a remote update solution so that the end-user does not need to send the UniKey dongle back to the software vendor. By using UniKey Remote Updater, the entire updating job can be done by simply clicking the mouse.

UniKey Remote Updater is secure. All the data is encrypted and protected by a 128-bit key.

UniKey Remote Updater provides a flexible updating scheme. By implementing updating criteria, software vendors can update a single UniKey dongle, a batch of UniKey dongles, or specific UniKeys with the correct SID.

Software vendors can also set a pass phrase to the UniKey Updater files (*.upt). Only the end-user with the correct password can use the file to update the UniKey dongle.